Sinotimer Svp916 Manual Version Pdf Full !new! -
Long-press the "Set" button for 3 seconds.
Protects against over-voltage, under-voltage, and over-current.
If you cannot find the PDF, email SINOTIMER support or your local distributor. Provide the serial number on your device’s side label. They will email you the full PDF version within 24-48 hours. sinotimer svp916 manual version pdf full
: Over-voltage protection triggered. The voltage exceeded your P01 metric. It will auto-restore when voltage drops below P02 .
The manual specifies entering parameter Fty (Factory) and setting it to 1 . Warning: This erases all custom settings. Long-press the "Set" button for 3 seconds
Warning: Many third-party PDF sites contain malware. Always download manufacturer manuals from trusted sources.
| Step | Parameter | Default | Range / Options | How to Interpret | | :--- | :--- | :--- | :--- | :--- | | | Overvoltage Protection Value | 280V | 221V - 300V (or OFF) | Sets the voltage threshold that will trigger an overvoltage trip. | | 2 | Overvoltage Reset Value | 250V | 220V - 299V | The voltage must drop below this value before the relay will re-engage after an overvoltage fault. | | 3 | Overvoltage Action Time | 0.1 sec | 0.1s - 10s | How long the voltage must exceed the overvoltage threshold before the device trips. A shorter time provides faster protection. | | 4 | Undervoltage Protection Value | 160V | 150V - 219V (or OFF) | Sets the voltage threshold that will trigger an undervoltage trip. | | 5 | Undervoltage Reset Value | 180V | 151V - 220V | The voltage must rise above this value before the relay will re-engage after an undervoltage fault. | | 6 | Undervoltage Action Time | 0.1 sec | 0.1s - 10s | How long the voltage must stay below the undervoltage threshold before the device trips. | | 7 | Fault Recovery Delay Time | 60 sec | 2s - 512s | The waiting period after voltage returns to normal before the device attempts to reconnect. | | 8 | Power-On Connection Delay | 2 sec | 2s - 255s | The delay before the relay closes to supply power after the device is first powered on or reset. | | 9 | Reset Mode Selection | AU (Auto) | AU (Auto) / HA (Manual) | Determines if the device automatically restores power after a fault (AU) or requires a manual button press (HA). | | 10 | Fault Code Inquiry | 1UL | Displays last 5 faults: UL (Undervoltage), UH (Overvoltage), 1UL (1st fault is undervoltage) | Use this diagnostic tool to review the cause and order of the last 5 protection events. Press UP (⯅) to cycle through the history. | | 11 | End | END | (N/A) | Signifies the end of the parameter list. Pressing SET here will save all changes and exit. | Provide the serial number on your device’s side label
The heart of the Sinotimer SVP‑916 manual is the . The device organizes all its settings into a sequence of 13 programmable parameters, labeled P01 through P13 . Mastering this menu is essential to customizing the relay to your specific electrical environment.