Eliwell Sb655 C Manual [better] Direct

Evaporator probe (Probe 2) failure. Often affects defrost termination.

Route probe and digital input cables away from high-voltage power lines to prevent electromagnetic interference.

: PC+ABS UL94 V-0 flame-retardant resin plastic casing.

Check digital inputs configured as external alarms (H11...H14). Open door alarm Check digital input status for door sensors (H11...H14). 5. Summary of Key Features

Dictates the evaporator temperature above which the fans will stop to prevent blowing warm air into the cabinet. Troubleshooting and Error Codes

If the unit remains locked, power cycle the controller (disconnect power for 30 seconds).

: This is a classic sensor-probe mismatch. The controller's input type (NTC or PTC) must match the installed probe.

: Includes modulating water pump control, dynamic defrost, and analogue condensation control. Advanced Features : Supports Free Cooling/Heating and power limitation to adapt to system demand. Electric Automation Network Basic Navigation & Programming

Selects the defrost method. 0 = electrical heater; 1 = hot gas injection; 2 = timed air defrost (compressor off).